Logo Aviso

A/B/S/UBM Ultrasound Platform
FDA Pending

 

  • 20Mhz B probe with 5 ring annular array technology
  • Enhanced UBM imaging
  • Patented motion sensor in B probes and UBM
  • DICOM standard display
ABSolu

Overview

NEW ANNULAR IMAGING

Quantel Medical has made a decisive leap forward with a new 5 ring annular technology on a 20 MHz probe. The principle is to emit alternating ultrasounds by 5 concentric transducers located in a single probe. 

The images thus obtained are spectacular as the entire eye is now visible with an exceptional level of detail. 

A SINGLE MULTIFUNCTION PROBE
 
The annular 5 ring 20 MHz B probe :
  • increases depth of field by 70%,
  • increases lateral resolution by 27%,
  • maintains high axial resolution. 
The annular technology allows to simultaneously examine pathologies of the vitreous, the retina and the orbital part.
NEW UBM IMAGING
 
UBM technology makes it possible to diagnose the structures behind the iris, that other technologies cannot visualize. 
Quantel Medical now offers optimised UBM technology: 
  • new signal processing for enhanced resolution and penetration,
  • linear transducer motion to optimise image quality,
  • electromagnetic technology to increase speed acquisition and comfort of use, 
  • ClearscanTM compatible: rapid and comfortable examination.

INTEGRATED MOTION SENSOR  
 
The B15, B20 and UBM probes are equipped with a position sensor that provides real-time essential information such as: 
  • the position of the probe on the eye,
  • the direction of the ultrasound beam.
This helps the operator to identify the area of examination more rapidly. 

REDESIGNED USER INTERFACE

Broad palette of measuring tools

 

Display in B+B mode for easy comparisons of examinations

Fully configurable patient report generator
 
  • DICOM IMAGING 1080p FULLHD
 
A world premiere in ophthalmic ultrasound: new Full HD screen with greyscale display compliant with section 14 of the DICOM standard.  
  • Constant and standardised image quality
  • Reliable image interpretation

ABSWITCH : 8 FUNCTION WIRELESS footswitch 

  • Adjustable Gain (+ and –).
  • Freeze/unfreeze image.
  • Viewing of Cineloop images (forward and reverse function).
  • Images saved in the patient’s file.
  • Tag on the Cineloop.

ABSwitch

Clinical

Videos

Published on 06 septembre 2018 / New ABSolu - the ultimate A/B/S/UBM ultrasound platform

Quantel Medical, global leader in ocular ultrasound, today presents its new A/B/S/UBM modular ultrasound platform: ABSolu. This new platform offers exceptional

Probes

Annular 5 ring 20 MHz probe

Annular 5 ring 20 MHz probe for visualize the entire eye with an exceptional level of detail. The principle is to emit alternating ultrasounds by 5 concentric transducers located in a single probe.

Transducer frequency: 20 MHz - Annular 5 rings   Depth of field: 20 mm (0.79'')
Angle of exploration: 50°   Axial resolution: 80 μm
Depth of exploration: 60 mm (2.36'')   Lateral resolution: 200 μm
Focus: 22 mm (0.87'')   Frame rate acquisition: up to 16 Hz

 

Biometry Probe

Axial length measurements probe

11 MHz Probe 
Adjustable gain: 20 to 110 dB
Time Gain Control (TGC): 0 to 30 dB
Transducer frequency: 11 MHz
Tip diameter: 6 mm (0.23”)
Electronic resolution: 0.04 mm (0.002”)
Depth: 40/80 mm on 2048 points
Contact and immersion techniques compatible.
Aiming beam: LED
  Axial length measurements
  Ultrasound propagation velocity adjustable per segment (anterior chamber, lens, vitreous) and IOL and vitreous material.
Built-in pattern recognition: dense, phakic, aphakic, PMMA, acrylic and silicone material for pseudo-phakic eye types
Automatic calculation of standard deviation and average total length (series of 10 measurements)
Acquisition modes: automatic, auto + save, manual
Automatic detection of scleral spike

Biometry Probe

Axial length measurements probe

Integrated laser pointer for biometry:

  • Ensuring the acquisition in the visual axis
  • Increasing the patient cooperation
  • Accelerating the speed of acquisition of A scans

Biometry laser pointer diagram

Biometry laser pointer

 

UBM probe

50MHz linear technology probe

50 MHz probe reveals what you can not see with OCT alone, enabling the operator to visualize the structures located behind the iris such as ciliary bodies, the processes and lens zonules.
Linear scanning offers the greatest signal intensity, providing superior anterior chamber image quality as the probe is always perpendicular with the tissue interface of interest.

 

Transducer frequency: 50 MHz   Focus: 9 to 11 mm
(0.35” to 0.43”)
Linear transducer movement: exploration width
16 mm (0.63”)
  Axial resolution:
Lateral resolution: 
35 μm
60 μm

Standardized A probe

Accurate examen of the eye

Digitally programmed S-shaped amplifier characteristics and comprehensive design  criteria for standardized echography and tissue differentiation according to Karl C. Ossoinig MD

Diagnosis functions featuring: Tumor Q1 ; Retina A1/Retina A2; Musc Profile
Probe Frequency: 8 MHz / parallel beam
Cineloop in A mode: Sequence up to 400 images recorded
Depth: Orbit 80 µs, Eye: 40µs, Zoom 20 µs
Separator Automatic tissue sensitivity determination with specific gain value recorded.
Distance measurement between 2 gates with adjustable velocity
Axial length measurement with cornea, A.C. depth, lens and vitreous differentiation.

15MHz B probe

General diagnosis probe

15 MHz Probe for eye and orbit examination. Automatic biometry readings obtained from a B mode image allowing axial length measurements for difficult to mesure long eyes or posterior staphyloma.
 

Transducer frequency: 15 MHz   Focus: 24 mm
(0.94”)
Angle of exploration: 50°    Axial resolution: 115 μm
Depth of exploration: 60 mm
(2.36")
  Lateral resolution:
Frame rate acquisition:
400 μm
up to 16 Hz
         

 

Accessories

Präger Shell 17 mm for Biometry (Adults)

Präger Shell 17 mm for Biometry (Adults)

Präger Shell 15 mm for Biometry (children)

Präger Shell 15 mm for Biometry (children)

Scleral Shell for Linear Probes ( 14, 16 or 18 mm)

Scleral Shell for Linear Probes ( 14, 16 or 18 mm)

ClearScan for 50MHz Linear Probe

ClearScan for 50MHz Linear Probe

Filmed windows for 2nd Gen 50Mhz Linear Probe

Filmed windows for 2nd Gen 50Mhz Linear Probe

ABSolu, A/B/S/UBM Ultrasound Platform

B Mode

Grey levels:  256
Adjustable gain:  20 to 110 dB
Adjustable Time Gain Control (TGC):   0 to 30 dB
Adjustable dynamic range: adjustement from 25 to 90 dB (for 15 and 50 MHz - 80 dB for 20 MHz 5A)
Image post-processing tools: filters (algorithm and colors), calipers, areas, angles, markers, comments
Glaucoma quantifying semi-automated tools: 

AOD 500 & 750, TIA, IT 750 & 2000, ARA 500 & 750, TISA 500 & 750, LV

Cineloop in B mode:

up to 400 images

 

Magnetic 15 MHz probe

Transducer frequency:  15 MHz
Angle of exploration:  50°
Depth of exploration:  60 mm (2.36'')
Focus:  24 mm (0.94'')
Depth of field:  12 mm (0.47'')
Axial resolution:  115 µm  
Lateral resolution:  400 µm 
Frame rate acquisition:  up to 16 MHz

 

 

 

 

 

 

 

Magnetic Annular 5 rings 20 MHz probe

Transducer frequency:  20 MHz - Annular 5 rings
Angle of exploration:  50°
Depth of exploration:  60 mm (2.36'')
Focus:  22 mm (0.87'')
Depth of field:  20 mm (0.47'')
Axial resolution:  80 µm  
Lateral resolution:  200 µm 
Frame rate acquisition:  up to 16 Hz

 

 

 

 

 

 

 

Magnetic 50 MHz UBM probe with linear scanning

Transducer frequency:   50 MHz
Linear transducer movement:  16 mm (0.63”)
Focus:  10 mm (0.39”)
Axial resolution:  35 μm
Lateral resolution:  60 μm

Digitally programmed S-shaped amplifier characteristics and comprehensive design criteria for standardized echography and tissue differentiation according to Karl C. Ossoinig, MD. Automatic tissue sensitivity determination with specific gain value recorded.

Diagnosis functions featuring: LESION Q1, Retina A1, Retina Q2, muscular profile with Optic nerve measurements
Probe frequency: 8 MHz parallel beam
Cineloop in A mode: up to 400 images
Depth: orbit 80 µs, eye: 40µs, Zoom 20 µs

Distance measurement between 2 gates with adjustable velocity.

Biometry

Adjustable gain:  20 to 110 dB
Time Gain Control (TGC):   0 to 30 dB


11 MHz probe

Transducer frequency:  11 MHz
Tip diameter:  6 mm (0.23”)
Electronic resolution:  0.04 mm (0.001”)
Depth of exploration: 40/80 mm sur 2048 points
Contact and immersion techniques compatible  
Aiming beam:  LED or laser pointer*


Axial length measurements

Ultrasound propagation velocity adjustable per segment (anterior chamber, lens, vitreous) and IOL and vitreous material

Built-in pattern recognition:  phakic, Dense/Long, aphakic, PMMA, acrylic and silicone material for pseudo-phakic eye types
Automatic calculation of standard deviation and average total length series of 10 measurements
Acquisition modes:  automatic, auto + save, manual 
Automatic detection of scleral spike  


IOL Calculation

SRK-T, SRK 2, HOLLADAY, BINKHORST-II, HOFFER-Q, HAIGIS
Post-op refractive calculation:
- Pre-op and Post-op refraction, Pre-op and Post-op keratometry
- 6 different methods for keratometric correction and implant calculation:
History derived, refraction derived, contact lens method, Rosa regression, Shammas regression, Double K/SRK-T (Dr. Aramberri’s formula)
9 values bracketed for desired ametropia for each IOL (IOL increment steps: 0.25D or 0.50D)
Simultaneous display of 4 different IOL calculations

Specifications are subject to change without notice.
©2018. Quantel Medical, ABSolu™ is a registered trademark of Quantel Medical. All rights reserved.

?
Brochure
Ask a question