Logo Vitra 2

SingleSpot or MultiSpot laser
532nm Retinal Photocoagulation

  • SingleSpot or MultiSpot laser
  • Adaptable on Haag Streit type or Zeiss type slit lamps
  • New generation of laser cavity
  • Laser delivery systems
Vitra 2

Overview

Vitra 2Technology

  • New generation of laser cavity (1500mW at tissue)
  • Multi terminal compatibility
  • Slit Lamp adapters (Haag Streit and Zeiss types)

Enhanced treatment options

  • SingleSpot Mode
  • MultiSpot Mode
  • Resume® Function

Enhanced Software User Interface

  • Software-guided treatment procedures
  • Customizable treatment settings
  • Treatment report

Ease to use

  • Control of the laser settings thanks to the analog knob, touch screen and wireless footswitch (optional)
  • Control of the patterns settings thanks to the touch screen and analog «click wheel» (with MultiSpot laser adapter only)

 

VITRA 2: SingleSpot or MultiSpot laser

SingleSpot Mode
Characterized by the use of long pulse durations (100-200ms), the SingleSpot treatment mode offers 4 customizable shooting modes for the implementation of thermal treatments such as leaking blood vessels sealing (focal laser photocoagulation): Single Mode, Repeat Mode, Painting Mode, Continuous Mode.

MultiSpot Mode
Characterized by the use of short pulse durations (10-20ms), the MultiSpot treatment mode offers many advantages over conventional photocoagulation in retinal treatments such as panretinal photocoagulation (PRP):

  • Less heat diffusion to the retina and choroid, less damage to the retinal nerve fiber layer [1,2]
  • Comfortable treatment better tolerated by patients [3]
  • Extremely fast treatment (full PRP in 1 session) [4]
The MultiSpot treatment mode can be delivered through 4 customizable patterns for better adaptation to the treatment site: Square, Circle, Triple arcs, Single Spot.

Vitra 2: Technology

In order to address the specific needs of each configuration, Vitra 2 slit lamp adapters are available in two versions:

Haag Streit Type Zeiss Type
Lampe à fente Haag Streit Lampe à fente type Zeiss
Haag Streit type slit lamp adapters: 
Removable SingleSpot laser adapter
Removable MultiSpot laser adapter
Integrated MultiSpot laser adapter
Zeiss type slit lamp adapters:
Removable SingleSpot laser adapter
Removable MultiSpot laser adapter
 

Vitra 2: Enhanced software user interface ​

Vitra 2 provides an intuitive and versatile software user interface simplifying the SingleSpot and MultiSpot laser treatments
Built in a clinically oriented manner, it guides the operator through the laser treatment implementation steps.

SingleSpot MultiSpot
Monospot MultiSpot

 

Vitra 2 features the proprietary Resume function allowing  the user to deliver a pattern in several steps or to resume the pattern delivery where the treatment was paused.

  1. Jain A, Blumenkranz MS, Paulus Y et al. Effect of pulse duration on size and character of the lesion in retinal photocoagulation. Arch Ophthalmol. 2008; 126:78-85.
     
  2. Yi-Ryeung Park, Donghyun Jee. Changes in Peripapillary Retinal Nerve Fiber Layer Thickness after Pattern Scanning Laser Photocoagulation in Patients with Diabetic Retinopathy. Korean J Ophthalmol 2014;28(3):220-225.
     
  3. Hussainy S Al, Dodson PM and Gibson JM. Pain response and follow-up of patients undergoing panretinal laser photocoagulation with reduced exposure times. Eye. 2008; 22, 96–99
     
  4. Muqit MM, Marcellino GR, Henson DB et al. Single-Session vs Multiple-Session Pattern Scanning Laser Panretinal Photocoagulation in Proliferative Diabetic Retinopathy. Arch Ophthalmo. 2010;128(5):525-533

 

Clinical

Videos

Published on 27 juin 2018 / VITRA 2: Quantel Medical reinvents its flagship 532nm green photocoagulator

After a successful career spanning more than 13 years, with more than 3000 units sold worldwide, Quantel Medical is proud to announce the renewal of its 532nm f

Delivery Systems

Operating Microscopes Laser Adapter

Zeiss & Leica

Adaptation laser pour microscopes opératoiresAdaptation pour microscopes opératoires permettant
le traitement laser de patients en position couchée.

 

Adaptor for Keeler Vantage Plus LIO

Adaptable laser delivery system

Adaptor for Keeler Vantage Plus LIO

577nm Adaptor for KEELER VANTAGE PLUS
IndirectOphthalmoscope (fiber size :100μ)

Heine Omega 500 Integrated LIO

Integrated laser delivery system

Heine Omega 500 Integrated LIO

Laser Indirect Ophthalmoscope Heine Omega 500
with Integrated Adaptor 577nm (fiber size: 100μ)

Steerable Probes

23G and 25G

Available in 23G and 25G sizes
• Exclusive design: Pressure-controlled curvature
  from the handpiece
• Adjustable curvature angle (0 - 90°) for a full
  coverage of the peripheral retina
• 360° rotatable handle for an ideal probes handover
           • Trocar cannulas compatible
           • Returns is straight position when releasing the
             handle for a safe needle withdrawn
           • Compatible with a wide range of laser’s connectors
           • 3 years expiration dates


                     For more information visit our laser probes page STEERABLE

Flexible Curved Probes

23G and 25G

Available in 23G and 25G sizes
• Wide curvature angle (45°) for an easy access
  to the peripheral retina
• Flexible needle (memory shape effect) for a perfect
  compatibility with trocar cannulas
• 3 years expiration date
           • One piece needle design ensuring a safe probe
              insertion (no steps)
           • Optimized hand pieces for an ideal probes handover
           • Compatible with a wide range of laser’s connectors

 


                  For more information visit our laser probes page FLEXIBLE CURVED

Straight & Curved Probes

20G, 23G and 25G

Straight laser probe Curved laser probe
Available in 20G, 23G and 25G sizes Available in 20G sizes
• Used for a direct access to treatment site
• Optimized handpiece for an ideal probe handover
• Compatible with a wide range of laser’s connectors
• 3 years expiration dates
• Used for the treatment of the peripheral retina
• Optimized handpiece for an ideal probe handover
• Compatible with a wide range of laser’s connectors
• 3 years expiration dates


                  For more information visit our laser probes page     STRAIGHT & CURVED

Accessories

Elbow Rest

Elbow Rest

Gentle Foot

Gentle Foot

Vitra 2

 
 
Vitra 2 Spécifications   
Laser: Frequency doubled Nd:YAG
Wavelenght: 532nm Green
Maximum power: 1500 mW (at tissue)
Pulse duration: 10 ms to continuous
Repeat interval: 0,1 - 0,2 - 0,3 -0,5 and 0,7 s
Aiming beam: 635 - 650 nm
Size: 14,5 (H) x 18,5 (L) x 30 (P) cm
7.1''(H) x 7.7''(W) x 11.8''(D)
Weight: 5.6kg - 12.3lbs
Cooling: By Peltier effect
Power requirements: 100 to 240 VAC, 250 VA, 50/60 Hz

 

 

SingleSpot Slit Lamp Adapters:

 

Emission modes: Single, repeat, painting, continuous
Spot size: 50 µm to 500 µm
Slit Lamp Compatibility:       Quantel Medical slit lamp, Haag Streit BM & BQ and clones, Zeiss 30SL, 120SL and 130SL and clones
Lasers: Optimis 2 and Optimis Fusion

 

MultiSpot Slit Lamp Adapters:                          Vitra Multispot 532 nm - Patterns Laser                              

 

MonoSpot Mode:  
Emission modes:       Single, Repeat, Painting, Continuous
Spot size: 50 µm to 400 µm
   
MultiSpot Mode:  
Patterns:  Square, Circle, Triple arcs, Single Spot
Spot size: 100 µm to 400 µm
Resume® function  
Slit Lamp compatibility: Quantel Medical Slit Lamp, Haag Streit BM & BQ and clones, CSO SL9800
Lasers: Optimis 2 and Optimis Fusion
                                                    

                        

                                                       
 

Haag Streit type slit lamp adapters:

  • Removable SingleSpot laser adapter
  • Removable MultiSpot laser adapter
  • Integrated MultiSpot laser adapter
 

Zeiss type slit lamp adapters:

  • Removable SingleSpot laser adapter
  • Removable MultiSpot laser adapter

Model still available in some countries according to local registration. For further information, please contact us.

Vitra Multispot 532 nm

Vitra Multispot specifications
Laser: Frequency doubled Nd:YAG, 532 nm
Power at tissue up to: 1500 mW
Pulse duration: 10 ms to continuous
Aiming beam: 635 - 650 nm
Size: 14.5 (H) x 18.5 (W) x 30 (D) cm
5.7’’ (H) x 7.3’’ (W) x 11.8’’ (D)
Weight: 4.7 kg – 10.4 lbs
Cooling: by Peltier effect
Power requirements: 100 à 240 VAC, 350 VA, 50/60 Hz

Model still available in some countries according to local registration. For further information, please contact us.

Vitra Monospot 532 nm Laser




 

Vitra Monospot specifications
Laser Source: Frequency doubled Nd:YAG, 532 nm
Power at tissue up to: 1200 mW
Pulse duration: 20 ms à continu
Repeat interval: 0,1 - 0,2 - 0,3 -0,5 et 0,7 s
Aiming Beam: 635 - 650 nm
Size:  14,5 (H) x 18,5 (L) x 30 (P) cm
5.7’’ (H) x 7.3’’ (W) x 11.8’’ (D)
Weight:  4.7 kg - 10.4 lbs
Cooling: By Peltier effect
Power requirements: 100 à 240 VAC, 350 VA, 50/60 Hz

Specifications are subject to change without notice.
©2018. Quantel Medical, Vitra 2™ is a registered trademark of Quantel Medical. All rights reserved.

?
Brochure
Ask a question