Compact Touch Logo
 

   3 in 1 Ultrasound System
     A/B Scans and Pachymetry

 

  • Portable A/B scan and pachymetry system
  • Built-in database and EMR compatibility for data storage
  • Biometry and IOL calculation
Compact Touch

Overview

Superior B Scan visualization

Thanks to Quantel Medical’s proprietary technology incorporated in B-scan probes, Compact TouchTM offers high resolution B mode images achieving better visualization and differentiation of structures and pathologies.

Precision in A Scan and IOL calculation

Ultrasound biometry is the only technology that allows measurements in all eye types including when dense cataracts are present.

Compact TouchTM biometry option provides high precision axial length measurements, meeting the needs of advanced IOL types and calculations.

Easy to use

Work faster and smarter with this easy-to-transport ultrasound platform. Compact TouchTM also offers an intuitive user interface accessible through a touch screen panel.

Easy glaucoma screening with the pachymetry option

With a precision of ± 5 microns, the pachymetry module allows fast and accurate corneal thickness measurements.

Superior B Scan visualization

Thanks to Quantel Medical’s proprietary technology incorporated in B-scan probes, Compact TouchTM offers high resolution B mode images achieving better visualization and differentiation of structures and pathologies.

New High Frame Rate functionality provides real time imaging when kinetic examination is crucial.

Whether with still images or video sequences, Compact TouchTM provides the examiner the ability to obtain diagnosis with complete confidence.

B mode also allows for biometry in myopic patients with staphyloma and Compact Touch’s software offers automatic A-scan measurement from B-scan for immediate IOL calculation.

Precision in A-scan and IOL calculation

Ultrasound biometry is the only technology that allows measurements in all eye types including when dense cataracts are present.

Compact TouchTM biometry option provides high precision axial length measurements, meeting the needs of advanced IOL types and calculations.

Together with the contact technique, immersion biometry is available to avoid any compression of the anterior chamber.

Scleral echo discrimination automatically eliminates optic nerve scans.

Quantel Medical’s ProBeam™ is a biometry probe with built-in laser pointer that permits automatic focusing in the visual axis.

The IOL calculation function allows comparison between different IOL types and calculation formulae. A total of 12 IOL calculation formulae are available including post-refractive surgery formulae.

Compact TouchTM offers a unique biometry in B mode feature allowing the automatic A-scan acquisition from a B mode image

Easy glaucoma screening with the pachymetry option

With a precision of ± 5 microns, the pachymetry module allows fast and accurate corneal thickness measurements.

Built-in IOP correction calculation tables provide the ability to ajust for variations in intra-ocular pressure.

For refractive surgery, several measuring modes and corneal maps are available.

Mobile versatility

Either with its built-in patient and user databases, and EMR compatiblity, Compact TouchTM is a transportable ultrasound platform that connects to most of compatible softwares for data storage and have an unlimited access to information.

Work faster

The intuitive user interface is accessible through a touch screen panel.

Easy and quick access to all functions speeds up image capture and processing.

Work smarter

Still images and video sequences can be reviewed easily in order to select the best scan.

Post processing of the images includes adjustment of the gain on a frozen image, distance and area measurements as well as input of comments.

Downloads

Use of B Mode Biometry for IOL Calculation

Cental Corneal Thickness in the Ocular Hypertension Treatment Study (OHTS)

B-mode guided vector A mode vs A-mode biometry to determine axial length and intraocular lens power

Probes

B Probe 10 MHz

General diagnosis probe

10 MHz Probe for eye and orbit examination. Automatic biometry readings obtained from a B mode image allowing axial length measurements for difficult to mesure long eyes or posterior staphyloma.
 

Transducer frequency: 10 MHz   Focus: 21 to 25 mm
(0.83” to 0.98”)
Angle of exploration: 50°    Axial resolution: 150 μm
Depth of exploration: 20 to 60 mm
(0.79" to 2.37")
  Lateral resolution:
Frame rate acquisition:
300 μm
up to 16 Hz
         

 

Biometry Probe

Axial length measurements probe

11 MHz Probe 
Adjustable gain: 20 to 110 dB
Time Gain Control (TGC): 0 to 30 dB
Transducer frequency: 11 MHz
Tip diameter: 6 mm (0.23”)
Electronic resolution: 0.04 mm (0.002”)
Depth: 40/80 mm on 2048 points
Contact and immersion techniques compatible.
Aiming beam: LED
  Axial length measurements
  Ultrasound propagation velocity adjustable per segment (anterior chamber, lens, vitreous) and IOL and vitreous material.
Built-in pattern recognition: dense, phakic, aphakic, PMMA, acrylic and silicone material for pseudo-phakic eye types
Automatic calculation of standard deviation and average total length (series of 10 measurements)
Acquisition modes: automatic, auto + save, manual
Automatic detection of scleral spike

Biometry Probe

Axial length measurements probe

Integrated laser pointer for biometry:

  • Ensuring the acquisition in the visual axis
  • Increasing the patient cooperation
  • Accelerating the speed of acquisition of A scans

Pachymetry Probe

Corneal thickness measurement



Perfect for glaucoma screening

Pachymetry has proven to be an essential tool in predicting glaucoma progression and helping patients management.

Pachymerty probe allows for a quick and reliable measurement of the central corneal thickness thanks to its 20 MHz probe.

Accessories

Präger Shell for Biometry (Adults)

Präger Shell for Biometry (Adults)

Präger Shell for Biometry (children)

Präger Shell for Biometry (children)

Scleral Shells for Biometry

Scleral Shells for Biometry

More Accessories

BeamBox Laser pointer
Probe Holder
Finger Grip Sleeve for 2nd Gen. B Probe
Extension Handle for Biometry Probe
Book - Clinical Echography of the Eye and Orbit Monograph
Scleral Shells for B mode (19-22-24 mm) and Biometry (16-18-20-22-24 mm)
Scleral Shell for Linear Probes (14-16-18 mm)
USB Hub
USB Laser Printer
USB Sony Video Printer
USB Probe Parameters
250 ML Gel for Echographe

 

 

Compact Touch - B Mode

B Mode

Grey levels:  256
Adjustable gain:   20 to 110 dB
Time Gain Control (TGC):    0 to 30 dB
Dynamic range adjustment:   25 to 90 dB 
Storage of still images and video sequences  up to 10 second duration on hard disk 
Image post-processing tools:  calipers, areas, markers, comment

10 MHz probe

Transducer frequency:  10 MHz
Angle of exploration:  50°
Depth of exploration:  20 to 60 mm (0.79" to 2.36")
Focus:  24 to 26 mm (0.94” to 1.02”)
Axial resolution:  200 µm  
Lateral resolution:  600 µm 
Frame Rate Acquisition:   up to 16 Hz

 

Biometry

Adjustable gain:  20 to 110 dB
Time Gain Control (TGC):   0 to 30 dB


11 MHz probe

Transducer frequency:  11 MHz
Tip diameter:  6 mm (0.23”)
Electronic resolution:  0.03 mm (0.001”)
Depth: 40/80 mm sur 2048 points
Contact and immersion techniques compatible  
Aiming beam:  LED or laser pointer*


Axial length measurements

Ultrasound propagation velocity adjustable per segment (anterior chamber, lens, vitreous) and IOL and vitreous material

Built-in pattern recognition:  phakic, aphakic, PMMA, acrylic and silicone material for pseudo-phakic eye types
Automatic calculation of standard deviation and average total length series of 10 measurements
Acquisition modes:  automatic, auto + save, manual 
Automatic detection of scleral spike  


IOL Calculation

SRK-T, SRK 2, HOLLADAY, BINKHORST-II, HOFFER-Q, HAIGIS
Post-op refractive calculation:
- Pre-op and Post-op refraction, Pre-op and Post-op keratometry
- 6 different methods for keratometric correction and implant calculation:
History derived, refraction derived, contact lens method, Rosa regression, Shammas regression, Double K/SRK-T (Dr. Aramberri’s formula)
7 values bracketed for desired ametropia for each IOL (IOL increment steps: 0.25D or 0.50D)
Simultaneous display of 4 different IOL calculations

Pachymetry

 

Transducer frequency: 20 MHz
Tip diameter: 1.2 mm (0.05’’)
Method: contact
Convergence : 0.5 mm (0.02”) from the tip
Angle :  45°

 

Corneal thickness measurements
Measurement range: 200 to 999 microns
Number of measurements: 1 to 10
Precision: ± 5 microns
Velocity:  adjustable
Methods: central measurement or cartographic map (automatic, continuous, scanning)
Cartographic map: user – 8L – 4L – 9C8L – 9C4L – 5C8L – 5C4L – 9C – 5C
I.O.P. correlation tables
Tables correlating intraocular eye pressure and corneal thickness:
Ehlers + Doughty + Dresdner + unlimited user-defined tables
 
Specifications
Bias correction: up to 120%

Quantel Medical Technology

General Information
Back-lit LCD colour touch screen monitor (resolution 1024x768)
 
Electrical requirements
Power supply: 100-240 Vac ± 10% single phase without earth
Frequency: 47-63 Hz
Power: 70 VA max
   
Features
Overall dimensions: 37.5 cm (L) x 10 cm (l) x 27 cm (H)
14.76" (W) x 3.94" (D) x 10.63" (H)
Dimensions de l'écran tactile : 21 cm (l) x 16 cm (H)
8.27" W) x 6.3" (H)
Poids : 4,2 kg (9.26 lb)
Ports: 2 USB, 1 ethernet
   
Data Management
Built-in physician and patient database
Exportation of still images and video sequences
Customizable digital and printed reports
EMR compatible
Compatible with PC, USB video


* Option 

Specifications are subject to change without notice.
©2017. Quantel Medical, Compact Touch™ is a registered trademark of Quantel Medical. All rights reserved.

?
Brochure
Ask a question